Radwag Pue 7.1.Wwg2, Pue 7.1 Terminal With Display Wwg-2

4.9 stars, based on 98 reviews

Radwag, PUE 7.1.WWG2, PUE 7.1 Terminal with Additional Display Model WWG-2 for Scales and Balances Terminal PUE 7.1 series is designed for extension of industrial scales





  • Description
  • 100001 is saved, the measurement 1 gets automatically deleted from the memory

    12860 g 961 IR Sensors - Programmable function supporting the weighing process through control of the following options sliding weighing chamber doors, printout, zeroing, tarring etc

    A graphic visualization of weighing result is displayed in a form of a bar graph

    Alibi Memory - Alibi memory enables saving and storing up to 100000 measurements

    Animal Weighing - Process of mass determination for a product which may unwillingly reposition within the weighing pan

    Area of use Mainly WWG-2 large size display is used as - Additional equipment for load cell industrial scales and for Increasing scale functionality or presentation of weighing result on a large size display.

    Checkweighing - Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low LO and High HI

    Current state of a sample being measured is signaled by means of pictograms located on a display for laboratory balances, for industrial scales Stack Light System is used

    Differential Weighing - Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes

    Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series

    Dosing function performance is often supported with bar graph - load indicator

    Dosing tolerance is given in and it is calculated in relation to the reference value thus being a permissible deviation of this process

    Each measured product is compared to mass standard, mass of which is presumed as a model 100 ideal mass

    Especially appreciated wherever preventing the balance from soiling is important

    For industrial scales it is possible to use a control systems of dosing process

    For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signaling base informing that specified number of items has been weighed

    For items counting the following algorithm is used all items mass / single item mass quantity

    For products weighing less than the mass standard, obtained results are lower than 100 , for products weighing more, the obtained results are greatly exceeded

    For systems based on a feed-back technique such information may be used by control units

    Formulation - Function supporting the mixture making process, wherein the mixture contains various components

    Formulation function usually uses the balance/scale database of components

    Formulation serves for monitored checkweighing of every single component with a given tolerance

    Function operation is supported by a mechanism of Automatic Correction of Accuracy

    Functions Dosing - Weighing process for which reference mass has been determined together with tolerance for its determination

    In laboratory the labeling is performed in a semi-automatic mode, for industry in an automatic one dynamic scales

    In such case standard deviation is the information which tells about quality and completeness of a final product

    It is enriched with a set of individual settings

    It is most often used in medical scales in order to hold the measurement indication

    It is possible to apply weighing systems using few platforms of different MAX capacities and different accuracies

    It is the user who defines period of time needed for control of measured product mass

    It may be either estimated through weighment or taken from a database

    Labeling - Marking products with the right symbols contributes to quick and reliable identification

    Large-size additional display, model WWG-2, is designed as a LCD display for cooperation with RADWAG scales

    Mass determination in such cases requires much longer period of time when compared to typical weighing process

    Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process

    Mass of a single item is required for this process

    Measurements are saved automatically upon each pressing of the key

    Measurements saved to balance memory cannot be deleted

    Newton Unit Measurement - Function allowing to perform the measurement in Newton unit, it may be used for processes aiming to determine force resulting in the sample damage

    PUE 71 features 5.7 colorful graphic touch screen display and membrane keypad

    Parts Counting - Function using mass measurement for determination of measured items quantity

    Peak Hold - Function registering the greatest temporary indication occurring in course of the weighing process

    Percent Weighing - Percent Weighing function is used for comparison of measured products with mass standard

    Plus/Minus Control - Control of sample's mass carried out with reference to specified MIN and MAX thresholds

    Statistics - Statistics function registers and analyses performed measurements

    The balance/scale usually transfers product mass or product quantity to the label printer

    The display is equipped with an assembly jig for hanging on a wall

    The display is placed in a stainless steel housing

    The following data related with the measurements is saved measurement date measurement time result mass tare value operator carrying out the measurement logged in product name

    The software saves the measurement in a so called loop, i.e

    The thresholds are given in g and kg units

    The transferred value is printed with the following information bar code, pictogram, content, address etc

    The user can thus optimize the function depending on the measured product characteristics

    The weight is considered to be correct if it is comprised within threshold values

    There is no need for any additional operations or changing settings

    This allows to determine mass content of the mixture, being a composition of number of different consistence components

    This allows to update single item mass in course of the process

    This solution is used for weighing powders, liquids and loose materials

    This supplies the user with the following information Max and Min standard deviation, average value, variance, range et

    This visual /- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specified tolerance, eg

    To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements

    Totalizing - Function adding new mass value to already obtained one

    Totalizing is limited by maximum capacity parameter

    Two proximity sensors with programmable functionality offer hands-free operation

    WWG-2 is an LCD large size display with diodes back lit in white color

    You can preview and print out the data saved to the Alibi database

    When the measurement no