Arrow
Radwag Pue 7.1.Wwg2, Pue 7.1 Terminal With Display Wwg-2
4.9 stars, based on 98 reviewsRadwag, PUE 7.1.WWG2, PUE 7.1 Terminal with Additional Display Model WWG-2 for Scales and Balances Terminal PUE 7.1 series is designed for extension of industrial scales
- Cart Add to Cart
-
USD 1856.00 In stock
- Description
-
100001 is saved, the measurement 1 gets automatically deleted from the memory
12860 g 961 IR Sensors - Programmable function supporting the weighing process through control of the following options sliding weighing chamber doors, printout, zeroing, tarring etc
A graphic visualization of weighing result is displayed in a form of a bar graph
Alibi Memory - Alibi memory enables saving and storing up to 100000 measurements
Animal Weighing - Process of mass determination for a product which may unwillingly reposition within the weighing pan
Area of use Mainly WWG-2 large size display is used as - Additional equipment for load cell industrial scales and for Increasing scale functionality or presentation of weighing result on a large size display.
Checkweighing - Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low LO and High HI
Current state of a sample being measured is signaled by means of pictograms located on a display for laboratory balances, for industrial scales Stack Light System is used
Differential Weighing - Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes
Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series
Dosing function performance is often supported with bar graph - load indicator
Dosing tolerance is given in and it is calculated in relation to the reference value thus being a permissible deviation of this process
Each measured product is compared to mass standard, mass of which is presumed as a model 100 ideal mass
Especially appreciated wherever preventing the balance from soiling is important
For industrial scales it is possible to use a control systems of dosing process
For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signaling base informing that specified number of items has been weighed
For items counting the following algorithm is used all items mass / single item mass quantity
For products weighing less than the mass standard, obtained results are lower than 100 , for products weighing more, the obtained results are greatly exceeded
For systems based on a feed-back technique such information may be used by control units
Formulation - Function supporting the mixture making process, wherein the mixture contains various components
Formulation function usually uses the balance/scale database of components
Formulation serves for monitored checkweighing of every single component with a given tolerance
Function operation is supported by a mechanism of Automatic Correction of Accuracy
Functions Dosing - Weighing process for which reference mass has been determined together with tolerance for its determination
In laboratory the labeling is performed in a semi-automatic mode, for industry in an automatic one dynamic scales
In such case standard deviation is the information which tells about quality and completeness of a final product
It is enriched with a set of individual settings
It is most often used in medical scales in order to hold the measurement indication
It is possible to apply weighing systems using few platforms of different MAX capacities and different accuracies
It is the user who defines period of time needed for control of measured product mass
It may be either estimated through weighment or taken from a database
Labeling - Marking products with the right symbols contributes to quick and reliable identification
Large-size additional display, model WWG-2, is designed as a LCD display for cooperation with RADWAG scales
Mass determination in such cases requires much longer period of time when compared to typical weighing process
Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process
Mass of a single item is required for this process
Measurements are saved automatically upon each pressing of the key
Measurements saved to balance memory cannot be deleted
Newton Unit Measurement - Function allowing to perform the measurement in Newton unit, it may be used for processes aiming to determine force resulting in the sample damage
PUE 71 features 5.7 colorful graphic touch screen display and membrane keypad
Parts Counting - Function using mass measurement for determination of measured items quantity
Peak Hold - Function registering the greatest temporary indication occurring in course of the weighing process
Percent Weighing - Percent Weighing function is used for comparison of measured products with mass standard
Plus/Minus Control - Control of sample's mass carried out with reference to specified MIN and MAX thresholds
Statistics - Statistics function registers and analyses performed measurements
The balance/scale usually transfers product mass or product quantity to the label printer
The display is equipped with an assembly jig for hanging on a wall
The display is placed in a stainless steel housing
The following data related with the measurements is saved measurement date measurement time result mass tare value operator carrying out the measurement logged in product name
The software saves the measurement in a so called loop, i.e
The thresholds are given in g and kg units
The transferred value is printed with the following information bar code, pictogram, content, address etc
The user can thus optimize the function depending on the measured product characteristics
The weight is considered to be correct if it is comprised within threshold values
There is no need for any additional operations or changing settings
This allows to determine mass content of the mixture, being a composition of number of different consistence components
This allows to update single item mass in course of the process
This solution is used for weighing powders, liquids and loose materials
This supplies the user with the following information Max and Min standard deviation, average value, variance, range et
This visual /- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specified tolerance, eg
To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements
Totalizing - Function adding new mass value to already obtained one
Totalizing is limited by maximum capacity parameter
Two proximity sensors with programmable functionality offer hands-free operation
WWG-2 is an LCD large size display with diodes back lit in white color
You can preview and print out the data saved to the Alibi database
When the measurement no